WebMar 14, 2024 · The bonding conductor must be attached to the CSST gas piping system downstream of the point of delivery (either the natural gas meter or the LP 2nd stage regulator). The bonding clamp can be located at any location within the piping system. In general, the shortest bonding conductor will be the most effective. The grounding electrode system includes all of the grounding electrodes available and the grounding electrode conductor(s). All electrodes used must be bonded together into one common grounding electrode system in accordance with IFGC Section 310.2.3/IRC Section G2411.2.3. A separate grounding … See more The 2024 International Fuel Gas Code (IFGC) and International Residential Code (IRC) have reaffirmed (without any modifications) the … See more Arc-resistant (black) CSST is characterized by a thick black jacket or a multi-layer black jacket system. The single-layer black … See more Existing steel or copper piping systems must be retroactively bonded when modified by adding yellow (non-arc-resistant) CSST to the system regardless of the length of … See more
CSST Gas Lines – Installation and Bonding Requirements
WebThe cost to have a qualified electrician properly bond CSST per the manufacturer's specifications is most often inexpensive, however it can be more difficult if the home has a finished basement with drywall ceilings … WebDec 16, 2024 · Some 500,000 new homes in the United States have CSST installed each year. But since regulations directing how pipes are bonded and grounded were not … north georgia race track
CSST Gas Lines - Installation And Bonding Requirements
WebFeb 21, 2024 · CSST Bonding is used to reduce the possibility and severity of arcing between conductive systems when energized by a lightning strike on a CSST gas pipe or nearby. The CSST must be … WebNov 12, 2012 · IRC 2411.1.1 CSST. Corrugated stainless steel tubing (CSST) gas piping systems shall be bonded to the electrical service grounding electrode system at the point where the gas service enters the building. The bonding jumper shall be not smaller than 6 AWG copper wire or equivalent. WebBonding is used to prevent an electric shock to someone who would come in contact with the gas piping and other metal objects connected to the grounding system. Lightning strikes can result in an electrical surge and can possibly puncture a hole in the CSST. Proper bonding and grounding will reduce the risk of damage and fire from a lightning ... how to say flowers in chinese